Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Paediatr Anaesth ; 18(7): 663-6, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18482239

RESUMO

For a predicted difficult airway, oral intubation techniques are well established in pediatric anesthesia, but nasotracheal intubation remains a problem. There are many reports concerning this, but the risk of bleeding, added to the lack of cooperation make this procedure difficult and hazardous. We describe a modification of the nasal intubation technique in two stages. First an oral intubation and then exchanging the oral for a nasal tube, in the case of a 13-year-old boy affected by an advanced stage of cherubism. Oral intubation using a laryngeal mask technique has already been reported, but problems appear during the exchange procedure and even more when direct laryngoscopy is impossible. Fiberscopic control of the exchange, and the introduction of a Cook Exchange Catheter into the trachea through the oral tube before withdrawal, permits oxygenation of the patient and acts as a guide for oral tube reintroduction if required.


Assuntos
Obstrução das Vias Respiratórias , Querubismo/cirurgia , Tecnologia de Fibra Óptica/métodos , Intubação/métodos , Boca , Cavidade Nasal , Adjuvantes Anestésicos/administração & dosagem , Adolescente , Anestésicos Intravenosos/administração & dosagem , Atropina/administração & dosagem , Querubismo/complicações , Humanos , Anormalidades Maxilomandibulares/etiologia , Anormalidades Maxilomandibulares/cirurgia , Máscaras Laríngeas , Imageamento por Ressonância Magnética , Masculino , Boca/diagnóstico por imagem , Boca/patologia , Procedimentos Cirúrgicos Ortognáticos , Piperidinas/administração & dosagem , Propofol/administração & dosagem , Remifentanil , Tomografia Computadorizada por Raios X
2.
Paediatr Anaesth ; 17(12): 1182-6, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17986037

RESUMO

BACKGROUND: Our aim in this study was to analyze the adjustment of the laryngeal mask, Ambu AuraOnce, in pediatric patients during magnetic resonance imaging (MRI) and to look for a correlation between clinical parameters such as the sealing pressure and the ease of introduction with radiological parameters. METHODS: One-hundred and twenty-one pediatric patients from 4 months to 17 years who required a cranial MRI for other reasons were enrolled in the study. General anesthesia was induced with sevofluorane and no relaxant was used. Insertion attempts, sealing pressure, desaturation episodes and maintenance of anesthesia were recorded. Spontaneous ventilation was maintained throughout all procedures and no episodes of desaturation below 95% were seen. Patients without cough or pharyngeal pain were discharged after 1 h. Data were classified into three groups according to the size of the used laryngeal mask (group 1 for laryngeal mask number 1(1/2); group 2 for laryngeal mask number 2, and group 3 for laryngeal mask number 2(1/2)). Sagittal MRI cuts were reviewed to calculate neck flexion, laryngeal mask position and its relationship with the trachea. RESULTS: First-attempt introduction rate of the laryngeal mask was 96%, and it was 100% after a second attempt. Sealing pressure was 22.1+/-4.15 mmHg for group 1, 22.23+/-3.94 for group 2, and 23.83+/-3.28 for group 3. The angles between the laryngeal mask and the four first cervical vertebrae were calculated (group 1, 33.65+/-8.05; group 2, 28.09+/-6.65; group 3, 25.79+/-4.26). Distances between trachea and proximal and distal cuffs were measured to evaluate proper fitting of the laryngeal mask. Anomalous placement seen on MRI, using distances from proximal and distal cuff to trachea, occurred in 23.5% in group 1, 10.9% in group 2, and 13.8% in group 3. We found no correlation between this anomalous position of the laryngeal mask and sealing pressure or ease of introduction. CONCLUSIONS: The Ambu AuraOnce can be regarded as a safe product for airway maintenance in pediatric patients. No relationship was found between radiological measurements and sealing pressures.


Assuntos
Anestesia Geral , Anestesiologia/métodos , Anestésicos Inalatórios , Máscaras Laríngeas , Imageamento por Ressonância Magnética , Éteres Metílicos , Pediatria , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...